Nokia Care Suite PST 5.0 5.6.134.1513

There will be some problem when using dead flashing function in this version. I suggest you NOT update it.

New version of the Nokia Care Suite Product Support Tool 5.0 is available.

It provides support for the Nokia Windows Phones (Lumia), Nokia X and the latest Asha devices and products supported by the Testing and Tuning tool. Installation package and latest version of User Guide Document are attached.
For the products that are not supported in this release, old PST and Multi SW Updater version 2011.50.2 or Phoenix release needs to be used.

New features in the Care Suite 5.0

  • NCOM Support: All NOL users will be soon transferred to another domain Nokia.com (NCOM) which requires new authentication channel and credentials.
  • This release supports changing the credentials, account expiration scenario and usual FiRe login use case.
  • OS Integrity check for Nokia X devices. 
  • Support for new devices: RM-983, RM-984, RM-985, RM-1013, RM-1014, RM-1015, RM-1016, RM-1017, RM-1018, RM-1019, RM-1020, RM-1049, RM-1061, RM-1087.

Changes & Error corrections from previous version
N/A

Please note:
Offline installation: Uninstall previous version (5.5.132.1446) manually before installing this version.
Only the new Common Data Package Location (SR1315) is supported by default. If you need to use other Data Package Locations, they need to be added to the preferences manually.
Do not use Care Suite 4.0 and 5.0 simultaneously. They can be installed on the same PC and launched from the Nokia Application Launcher but not run at the same time.
If it seems that all features are not available on the left hand side of the screen, please click the small arrow next to the list. More features will be shown. This may happen if your screen is not maximized.
Lumia / Windows 7 phones will reboot when they are disconnected – please wait for the phone to restart
Installation of FUSE drivers may take a long time. Therefore it is recommended that the Windows Automatic Driver Installation is disabled from the Control panel. Please go to Windows Control Panel -> System ->Advanced System Settings ->Hardware ->Device Installation Settings and select “Never install driver software from Windows Update”
PC must be connected to network, meaning that Ethernet cable must be connected to PC and connection needs to be configured to work properly. PC must be able to connect to for example internal network, but it is not necessary that PC has an online connection to Internet.
Nokia X (RM-980). Note: For device detection, user needs to manually enter code: *#*#2273#*#* on device dial-pad and enable WinUSB mode by selecting it on device’s screen. Same action is always needed after finalized flashing.

Known errors & limitations
FLS-5 Drivers included in the installation package do not support 64-bit WIndows operating systems. Therefore Care Suite PST can not be used for servicing phones which use FLS-5 (USB_FBUS) connection.
Please do not use diacritical signs when selecting installation path for NCS.
Recovery or Refurbishment Flashing for Lumia Series Devices may fail on first attempt. Please try again, it works the second time around
Asha drivers don’t install when devices are connected via USB hub (on win7). Hub works if user installs drivers first via straight USB connection.
PST release 5.0 can be installed on the same PC with all current Nokia Service Software Applications, but simultaneous use with earlier PST version 4.0 is not possible
Audio input test with RM-899, RM-900 and RM-902 require AHJ headset.
In case of OMTP AV connector the microphone signal pin is switched with ground and the test fails silently.
(no error returned from the device).
Chess patterns do not work with RM-839, RM-840, RM-841, RM-948, RM-949, RM-950, RM-952, RM-953, RM-954, RM-956, RM-957.
The error is on device sw side.
Multi Software Updater 5.0 issues with devices RM-944 (Nokia 108 Dual SIM) and RM-945 (Nokia 108) Multi Software Updater 5.0 has some problem with multi refurbish for devices RM-944 (Nokia 108 Dual SIM) and RM-945 (Nokia 108).
In order to fix this problem please disable Refurbish Logs in preferences. Please follow the instructions below on how to solve this problem:

  1. Launch “Multi Software Updater 5.0” then go to menu File –> Preferences;
  2. In preference switch to “Logs” tab then uncheck Refurbish Logs Enable;
  3. Click Ok button

Windows Phone 8.1 devices having Dual SIM have IMEI reading issue in test mode. IMEI2 reading fails so that IMEI1 is shown also as IMEI2.
In normal mode, both IMEIs are read correctly.
Be extra-careful when flashing Nokia X RM-980 or RM-1030. Read and follow PST instructions carefully: Flashing wrong firmware will damage the device. Firmware is ok if product code is matching or the list of allowed hwids contains the device hwid.
After any flash operation of RM-1013, RM-1014, RM-1015, RM-1016, device mode says: “Mode read failed”. Reason for this is that during the first device boot after flashing device is unresponsive. It only happens right after flashing, during boot-up. By refreshing the connection you will get device mode to show “Normal” mode.

MSU
When using Multi SW Updater, the recommendation is to use it with up to five devices that are the same model and start the refurbish to every device simultaneously.
Do not start 1st flash-round with full amount of devices – instead add gradually 2-3 devices – Fuse can be fragile when 8-16 devices at once tries to create new connection
When using USB Hub please connect devices one by one to the ascending USB ports – it will help you to distinguish which of them had failed and needs to be recovered by Recovery plugin (check IMEI, USB Port # from UI or follow Action Report log for details)
Do not connect\disconnect devices while other flashings are in progress – all should be finalized (successful or not) – main reason for fail is USB port enumeration done by OS when changing something
Additional info for 16 simultaneous flashes: Based on testing with Windows Phone 8 devices please follow the following preliminary recommendations for a PC USB setup for maximum stability and timing of the USB bus:
Use a PC that has at least four (4) independent USB 2.0 host controllers.
Connect no more than one powered external USB hub to each host controller
Each external hub must have its own independent power source, with the capability to supply at least 500 mA per device connected to it.
Connect no more than four (4) devices to each external hub

Supported products:
RM-761, RM-763, RM-781, RM-799, RM-800, RM-813, RM-884, RM-803, RM-809, RM-807, RM-832, RM-834, RM-810, RM-811, RM-827, RM-837, RM-871, RM-808, RM-823, RM-802, RM-835, RM-836, RM-849, RM-724, RM-725, RM-819, RM-801, RM-596, RM-601, RM-609, RM-626, RM-639, RM-640, RM-659, RM-662, RM-670, RM-675, RM-679, RM-691, RM-692, RM-693, RM-694, RM-702, RM-704, RM-707, RM-718, RM-730, RM-749, RM-750, RM-754, RM-772, RM-774, RM-775, RM-776, RM-779, RM-766, RM-767, RM-768, RM-696, RM-714, RM-872, RM-873, RM-862, RM-863, RM-864, RM-824, RM-825, RM-826, RM-845, RM-867, RM-846, RM-852, RM-821, RM-820, RM-822, RM-889, RM-898, RM-907, RM-878, RM-838, RM-843, RM-911, RM-913, RM-914, RM-915, RM-917, RM-923, RM-885, RM-887, RM-860, RM-839, RM-840, RM-841, RM-919, RM-921, RM-924, RM-925, RM-926, RM-928, RM-929, RM-892, RM-893, RM-899, RM-900, RM-902, RM-910, RM-875, RM-876, RM-877, RM-927, RM-937, RM-938, RM-939, RM-940, RM-941, RM-942, RM-943, RM-948, RM-949, RM-950, RM-952, RM-953, RM-954, RM-955, RM-956, RM-957, RM-920, RM-922, RM-944, RM-945, RM-947, RM-951, RM-958, RM-959, RM-961, RM-962, RM-963, RM-994, RM-995, RM-996, RM-997, RM-998, RM-934, RM-972, RM-973, RX-113, RX-114, RM-969, RM-970, RM-971, RM-986, RM-987, RM-980, RM-1027, RM-1010, RM-974, RM-975, RM-976, RM-977, RM-978, RM-979, RM-1011, RM-1012, RM-1043, RM-981, RM-1053, RM-1030, RM-1042, RM-1045, RM-894, RM-895, RM-1017, RM-1018, RM-1019, RM-1020, RM-1098, RM-1013, RM-1014, RM-1015, RM-1016, RM-1061, RM-1087, RM-1049,RM-983,RM-984,RM-985

Nokia_Care_Suite_5.6.134.1513_1

Nokia_Care_Suite_5.6.134.1513_2

Nokia_Care_Suite_5.6.134.1513_3

If you can not install the Full Version, please download and install the MSI File(We have removed the FLS from the MSI file so you can install it correctly).

Full: Download Now

MSI: Download Now

Nokia Care Suite User Guide 1.7.16: Download Now

For India: Full / MSI / User Guide

34 Replies to “Nokia Care Suite PST 5.0 5.6.134.1513”

  1. admin, can re-upload that software nokia care suite 5.6 in
    i have done flash my lumia with nokia care suite 5.5 but can’t flash it

  2. nokia 130 rm-1035 is supported by care suite,
    tuto….make a folder name RM-1122 and paste all file of RM-1035 in it,now open care suite and flash the phone

    thanks

  3. after login care suite external not downloding firmware
    say- The underlying connection was closed: An unexpected err occurred on a receive.

    solution plz

  4. i have asha 201 but when i try to flash with BEST it says bad flash files. I have tried downloading different firmwares form different sites. but at the end i always get the same reason

  5. launching ProductSupportToolForStore 5 error msg:
    n FuseLib.FuseLoaderClass.CreateConnectionServices()
    in Nokia.CareSuite.Connectivity.FuseConnectivity.Load Fuse()
    in Nokia.CareSuite.Applications.ProductSupportToolFor Store.ProductSupportToolForStore.RunInternal()
    in Nokia.CareSuite.Applications.ProductSupportToolFor Store.ProductSupportToolForStore.Run()
    in Nokia.CareSuite.Applications.ProductSupportToolFor Store.ProductSupportToolForStore.Main()

    1. 2015-08-20 18:34:50Z | 3972 (ProductSupportToolForStore) | 0x00000001 | ProductSupportToolForStore.exe | Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore | Error | Application terminated abruptly. |
      2015-08-20 18:34:50Z | 3972 (ProductSupportToolForStore) | 0x00000001 | ProductSupportToolForStore.exe | Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore | Error | Application is being terminated due to unhandled exception. |
      2015-08-20 18:34:50Z | 3972 (ProductSupportToolForStore) | 0x00000001 | ProductSupportToolForStore.exe | Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore | Information | Assembly ‘Accessibility, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a’ has been loaded. |
      2015-08-20 18:36:24Z | 3972 (ProductSupportToolForStore) | 0x00000001 | ProductSupportToolForStore.exe | Nokia.CareSuite.Applications.ProductSupportToolForStore.SessionMutex | Information | Mutex released. |

  6. Retrieving the COM class factory for component with CLSID {6BCF7DCA-7B86-453E-BC72-724E0E656B95} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)).
    at Nokia.CareSuite.Connectivity.FuseConnectivity.LoadFuse()
    at Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore.RunInternal()
    at Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore.Run()
    at Nokia.CareSuite.Applications.ProductSupportToolForStore.ProductSupportToolForStore.Main()

  7. In the last Summer Care Suite gone several RM, Lumia 930, 730, 830, and still appears support for Microsoft devices, lumia 532, 435, 640, 640 XL.
    I would like a solution to upgrade these devices.

  8. I copy usergroupconfig from the previous version but when I try to dowload new firmware, it says “access is denied, verify credentials”

    Any Workaround?

  9. Hi, I already installed the software, but when I double click Product Support Tool nothing happens.

  10. I HAVE NOKIA XL RM-1030 CODE 059W180 AND I THINK THIS VERSION OF NOKIA CARE SUITE DOES NOT SUPPORT NOKIA XL RM-1030
    UPLOAD ANY CARE SUITE WHO THIS PHONE RM-1030 PLEASE HELP ME

      1. Thanks Seidea admin for upload.
        Can you also upload following 2 files
        1 ) Nokia Lumia 638 4G RM-1010 Service schematics v1.0.pdf

        2) Nokia Lumia 730 735 rm-1038 1039 1040 l1l2 service manual v2.0.pdf

Leave a Reply to amit mandal Cancel reply

Your email address will not be published. Required fields are marked *