Pheonix Service Software 2011.24.002.46258

Main component versions in the release:
DK2 Driver Version 07.14.0.25
Nokia Connectivity Cable USB Driver Version 7.1.42.0
Flash Update Package 2011.24.000
FLS-x Drivers Version 2.09.28
FUSE Connection Manager v 2011.25

MAIN CHANGES & ERROR CORRECTIONS FROM PREVIOUS VERSION 2011.14.4.45945
New Products added
RM-754, RM-755, RM-804, RM-696, RM-774, RM-761

Products removed
RM-738, RM-739

New features
New version of FUSE connection Manager
New version of Flash Update Package
New version of Autotuning components
New version of Product API
New version of Connectivity Cable Driver
Installation checks the PC for Microsoft DOT.NET 2 Service Pack 2 and installs it automatically if PC has online connectin to Internet. If DOT.NET version 2 SP 2 or newer is found, installation continues normally. If PC is not connected to internet, and DOT.NET needs to be updated installation will be aborted. In this case DOT.NET must be updated manually before installation of Phoenix can continue
Error Corrections & changes
Crash which occurred when Phone Information UI was open simulaneously with other menu´s has been corrected
The Envira Tool ( The ZIP package generator in Help / Troubleshooting – menu) now has a button to delete existing old log files. This makes it possible to clear old logs before reproducing / logging problems to new log files which are then easier to analyse.
“No Connection” – problem, which occurred when a connection without phone connected was selected has been corrected. Connection without phone can now be selected.
Please note:
Microsoft DOT.NET version 2 Service Pack 2 is now the minimum requirement. Phoenix installation will check PC for the DOT.NET version and update it automatically when PC has online connection. Without online connection, old DOT.NET versions must be updated manually.
New common data package location in use. Please see document SR1315 in KICS Information Center for further information.
All Nokia Service Software Applications will use following location for product specific data:
– Windows XP: C:Documents and SettingsAll UsersApplication DataNokiaPackages
– Windows 7: C:Program DataNokiaPackages
Please see atricles SR1774 and 1786 for more information on the use of Nokia Data Package manager – tool, and article SR1854 for more information on the Nokia Service Application Manager Tool.
During installation, Data Packages should be installed in these directories, if they install to any other location by default. target folder for local data packages can be changed in the installation wizard manually
This version contains the latest Tucson components. Therefore it is not necessary to use Tucson Add-On Installation Packages
Before you start Phoenix or Care Suite installation to Windows 7 the User Account Control (UAC) should be turned off from Windows Control Panel settings.
For more information concerning new options in “Firmware Update” – menu and their use, Please see documents SR1313 and SR1659 in KICS Information Center.
Tucson operations combined with “flash” – option are now handled in the same way as “refurbishment”, which requires Mass Memory Content File to be available.
Do not use Flash option simultaneously with product code change for USB Only phones, flash phone separately with Firmware Update
It is recommended to use FPS-21 flash prommer with TCPIP connection when refurbishing USB Only – phones (RM-596 etc) due to mandatory optional MMC file size.
Connection media to FLS-5 must be configured to be “USB_FBUS”, after FLS-4 support has been removed FBUS does not work anymore with FLS-5

Continue reading “Pheonix Service Software 2011.24.002.46258”

Phoenix Service Software 2010.24.003.43250

This version contains the latest Tucson components. Therefore it is not necessary to use Tucson Add-On Installation Package v.2010_10_9_41709.
Improvements concerning the case where phone models request SIM Lock data to be written in wrong format have been included. Therefore it is not necessary to use special DLL´s or Tucson Add-On Components for SIM Lock versions anymore.
For all Tucson activities, use of components included in this release is enough, please do not use any previously released Tucson – related dll´s or add on packages

Main component versions in the release:
DK2 Driver Version 07.14.0.25
Nokia Connectivity Cable USB Driver Version 7.1.27.0
Flash Update Package 10.20.001
FLS-x Drivers Version 2.09.28

Main changes & error corrections from previous version 2010.12.11.42838
New Products added
RM-684, RM-718, RM-693, RX-83, RX-85, RM-702, RM-688, RM-694, RM-695, RM-709, RM-639, RM-683, RM-666, RM-667, RM-712, RM-704, RM-711, RM-675, RH-125, RM-692

New features
Connection refresh – button added directly to Phoenix UI. Refreshing connection is now possible without opening FUSE Connection Manager separately, use of older “manual CU-4 initialization” – menu is not needed if CU-4 is paired with the connection and “refresh” – function is used.
New version of FUSE connection Manager
New version of Flash Update Package
Phoenix can now use product codes which contain alpha characters in addition to numbers

Continue reading “Phoenix Service Software 2010.24.003.43250”

Phoenix Service Software 2010.12.11.42838

This version contains the latest Tucson components. Therefore it is not necessary to use Tucson Add-On Installation Package v.2010_10_9_41709.

Main component versions in the release:
DK2 Driver Version 07.14.0.25
Nokia Connectivity Cable USB Driver Version 7.1.27.0
Flash Update Package 09.050.025
FLS-x Drivers Version 2.09.28

Main changes & error corrections from previous version 2010. 12.8.42304
New Products added :
RH-125

New features
New rf_losses.ini file for RF auto tuning
Support for RH-125 product enabled, Drivers for RH-125 adapter added to installation package
DCT-4 Product code changes can now be done for RH-125.
– Use EXTERNAL Smart Card Reader for SX-4 or 4T, follow reader specific instructions
– Install Phoenix with included Prolific drivers ( you many need to reboot PC during process)
– Install the latest RH-125 Data Package(s)
– Connect CA-101 USB Cable to PC USB Port, and SF-204 adapter to USB Cable
– Allow Windows to install drivers for SF-204 adapter
– Start Phoenix
– Configure connection from FUSE Connection Manager by using following Settings:
– Connection Type: FBUS
– Communication Port Type: USB-COM ( Please scan FBUS Devices from FUSE)
– Connect RH-125 product to SF-204 adapter, check that FUSE detects RH-125 product in connection (select correct connection from “Connections” – dropdown)
– Scan product from “File / Scan Product” – menu , or press CTRL+R
– Select “Product Code Change DCT-4” from “Tools” – menu
– The rest of the process is normal DCT-4 Product Code Change.
– NOTE: Do NOT select “Flash” – option, always perform product code change without flashing the phone when using Phoenix for RH-125.
– NOTE: After Product Code Change, flash the latest SW version matching new product code by using Nokia Care Suite. Phoenix should only be used for product code changes concerning SIM Locked variants. All other service activities for RH-125 should be done by using Nokia Care Suite

Continue reading “Phoenix Service Software 2010.12.11.42838”

Phoenix Service Software 2010.12.008.42304

Main component versions in the release:
DK2 Driver Version 07.14.0.25
Nokia Connectivity Cable USB Driver Version 7.1.27.0
Flash Update Package 09.050.025
FLS-x Drivers Version 2.09.28

MAIN CHANGES & ERROR CORRECTIONS FROM PREVIOUS VERSION 2010.8.4.41526
New Products added
RM-650, RM-627, RM-648, RM-682

New features
Nokia Connectivity Cable USB Driver Version 7.1.27.0
New Connection manager FUSE replaces old connection manager
Error Corrections & changes
WCDMA EVM testing issues with Willtek testers corrected, but SW update to Willtek tester is also required.SW must be updated to latest available version Please see https://www.willtek.com/english/nokia for more details
Ambient Light Sensor Calibration version corrected to version 1_3_0_40303
New Label Printing DLL to correct font and IMEI length problems
SW package download capabilities for FiRe / online use enhanced
MCF Upload correction
Improvements to decrease finalization delay in flashing related events
RF Final Test improvements for RM-586
Minor menu Changes

Continue reading “Phoenix Service Software 2010.12.008.42304”