Phoenix Service Software 2012.50.000.49146

Main component versions in the release:
Product API 2012.46.2.49145
Nokia Connectivity Cable USB Driver Version 7.1.101.0
Flash Update Package 12.49.0
FUSE Connection Manager v 2012.51.1

MAIN CHANGES & ERROR CORRECTIONS FROM PREVIOUS VERSION 2012.36.1.48629
Error Corrections & changes:
New products: RM-924, RM-925, RM-926, RM-911, RM-928, RM-929
Datapackage Download-menu removed. Use Datapackage Manager to download phone software. See article SR3456
Phone connectivity improved
All Nokia Service Software Applications will use following location for product specific data:
- Windows XP: C:\Documents and Settings\All Users\Application Data\Nokia\Packages
- Windows 7: C:\Program Data\Nokia\Packages

KNOWN ERRORS & LIMITATIONS
N9- RM-696 Product Code change still unreliable
Product code change is not working with RM-838, RM-852, RM-843. Please use Product identity tool (SR2872)
FLS-5 drivers do not support 64 bit OS, so phones using FLS-5 /USB_FBUS connection can not be serviced in 64 bit operating systems
Software downgrade with Tucson system is only possible for BB 5.0 products supporting the Data Package 2 concept.
Flashing with setup FLS-5, SS-46 and product specific adapter is not supported anymore. FLS-5 can be used with other product specific cables and adapters, but not with SS-46 Interface Adapter.
If you install old DCT-4 data packages, Flash Update Package File installation path may be wrong. This is caused by very old DCT-4 data packages which contain Flash Update Package and overwrite current information during installation. If you experience problems when updating FPS-x prommers, please check that Phoenix “Prommer maintenance” is looking for the files from the correct location which is “C:\Program Files\Common Files\Nokia\Tss\Flash”. If not, Phoenix will show error “Update via ini – file failed”. In this case, select “Update” from that Phoenix “Prommer maintenance” – UI, browse to correct directory and select “fpsxupd.ini” for all other prommers except the FPS-8.
FPS-21 flashing for RX-51 works only with TCPIP connection. FPS-21 prommer with new HW version 11 has been released to correct this. Sales pack code is 0089J83 , old HW version is not delivered anymore
Please refer to product specific documents and instructions concerning the limitations of the RX-51 product
When version 2010_12_8_42304 or newer with FUSE connection manager is installed on top of older Phoenix versions, there may be an additional delay of several minutes when you start Phoenix for the first time. Please wait patiently; Phoenix will start after configuration is finished.
After you close Phoenix, it may not restart. To rectify this:
- Use Windows Task Manager to manually shut down phoenix.exe and FuseService.exe processes, or optionally restart your PC
It is not possible to program Mass Media Content file to some devices over direct USB cable connection, due to the large size of the file. For these models a feature called “Media Check” has been implemented. When this type of product is connected to service software / PC via direct USB cable the refurbishment option will be disabled. Please use a flash prommer. Affected products using Media Check are: RM-122, RM-175, RM-176, RM-186, RM-246, RM-247, RM-296, RM-297, RM-320, RM-462, RM-472, RM-484, RM-505, RM-555, RM-559
To be able to use the help files in Windows 7 you need to install Windows Help program (WinHlp32.exe) for Windows 7. Ways to locate WinHlp32.exe:
- Start Phoenix with online connection to Internet, select “Help” and “Phoenix help”. Click the “Microsoft Help and Support” website link. Download WinHlp32 and install it.- Go to http://www.microsoft.com. Type “WinHlp32″ to “Search Microsoft.com” – field. Locate Windows Help program (WinHlp32.exe) for Windows 7 and install it
When using flash prommers, only one connection type to one prommer is allowed. Please use either NFPD USB or NFPD TCPIP connection to one prommer, not both connections to same prommer

Supported operating systems
Windows 7 32 Bit version
Windows 7 64 Bit version (Please note that FLS-5 drivers do not support Win 7 64 bit OS, therefore FLS-5 can not be used in this operating system)

IMPORTANT!
Phoenix installation requires a network connection if DOT.NET framework 4.0 is not installed on PC[Microsoft .NET Framework 4 (Standalone Installer)], if you have installed it, you can ignore this.
(.NET framework is downloaded from web during phoenix installation).

Original: Download Now

Cracked: Download Now

15 comments on “Phoenix Service Software 2012.50.000.49146”

  1. all the links are bad , i can’t download any version …. please give me new links tested , very important … many thanks to you

  2. Whenever i run this softwre, i get a error msg tht,
    Error loading component

    HRESULT 0×80040154 (-2147221164)
    This means:
    Class not registered

    Please do the needful…..

  3. After several tries I finally got the firmware update to run. I left the computer came back and phoenix advised the update was complete. However, the phone is still asking for a security code at boot.

    I then tried again but I’m getting the following error:
    Flashing finalization failed. Do you like to retry the finalizing?
    HRESULT 0x8421001c (-2078212068)
    Unable to get error message.

    Anyone have any insight on my issue?
    Thanks.

Leave a Reply

Your email address will not be published. Required fields are marked *

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>